Advanced search
Advanced search
Advanced search
Advanced search
Advanced search
The influence of the tower air-lift bioreactor geometry on the oxygen transfer rate in the apparatus
Committee on Biotechnology PAS ; Institute of Bioorganic Chemistry PAS
The hydrodynamic and mass transfer parameters in water, in several types of tower-loopair-lift bioreactor were investigated. The following configurations of the apparatus were used forexperiments: internal-loop with eentral draft tube, internal-loop with static mixers in the drafttube, external-loop with various circulation tube diameters (0 < A^/Ar < 1), external-loop withperforated plates in the main zone (multistage reactor). The highest k^a eoefficients were obtainedin external-loop multistage reactor. A^/A^ ratio had significant influence on the main processparameters; gas holdup, liquid circulation velocity, volumetric oxygen transfer coefficient andmixing time.
Biotechnologia, vol.22, 3 (1993)-.
0860-7796 ; oai:rcin.org.pl:154153 ; IChB B-18
Library of Institute of Bioorganic Chemistry PAS
Creative Commons Attribution BY-SA 4.0 license
Institute of Bioorganic Chemistry of the Polish Academy of Science
Institute of Bioorganic Chemistry of the Polish Academy of Science
Dec 31, 2020
Dec 31, 2020
688
https://rcin.org.pl./publication/187280
Edition name | Date |
---|---|
Wpływ konstrukcji bioreaktora wieżowego air-lift na szybkość wnikania tlenu do fazy ciekłej | Dec 31, 2020 |
Starzak, Maciej Głuszcz, Paweł Michalski, Henryk
Głuszcz, Paweł Jamroz, Teresa Michalski, Henryk Sencio, Barbara
Borkowska, Bożenna
Ziółkowski, Piotr Babula- Skowrońska, Danuta Kaczmarek, Małgorzata Cieśla, Agata Sadowski, Jan
Michalski, Henryk Jamroz, Teresa Sencio, Barbara