The influence of the tower air-lift bioreactor geometry on the oxygen transfer rate in the apparatus
Inny tytuł:The influence of the tower air-lift bioreactor geometry on the oxygen transfer rate in the apparatus
Twórca:Głuszcz, Paweł ; Michalski, Henryk
Wydawca:Committee on Biotechnology PAS ; Institute of Bioorganic Chemistry PAS
Data wydania/powstania: Temat i słowa kluczowe: Abstrakt:The hydrodynamic and mass transfer parameters in water, in several types of tower-loopair-lift bioreactor were investigated. The following configurations of the apparatus were used forexperiments: internal-loop with eentral draft tube, internal-loop with static mixers in the drafttube, external-loop with various circulation tube diameters (0 < A^/Ar < 1), external-loop withperforated plates in the main zone (multistage reactor). The highest k^a eoefficients were obtainedin external-loop multistage reactor. A^/A^ ratio had significant influence on the main processparameters; gas holdup, liquid circulation velocity, volumetric oxygen transfer coefficient andmixing time.
Czasopismo/Seria/cykl:Biotechnologia, vol.22, 3 (1993)-.
Tom: Zeszyt: Strona pocz.: Strona końc.: Typ zasobu: Szczegółowy typ zasobu: Format: Identyfikator zasobu: Źródło:Library of Institute of Bioorganic Chemistry PAS
Język: Język streszczenia: Zakres czasowy: Prawa:Creative Commons Attribution BY-SA 4.0 license
Zasady wykorzystania: Digitalizacja:Institute of Bioorganic Chemistry of the Polish Academy of Science
Lokalizacja oryginału:Institute of Bioorganic Chemistry of the Polish Academy of Science
Dofinansowane ze środków: Dostęp: